Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38.192
Filtrar
1.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1535336

RESUMO

Introduction: The purpose of this article is to discuss in-office laryngeal procedures as an alternative to surgical intervention under general anesthesia. In-office procedures have become more common due to technological advancements. As a result, these approaches are less invasive and more patient-friendly, with increased pain tolerance and reduced procedure time and cost. Methods: We conducted a thematic analysis of published reports regarding the best known and performed in-office laryngeal interventions. Three questions guided our analysis: What laryngological procedures can be performed in the office setting? What are the advantages of in-office laryngology procedures compared to operating room surgical procedures? Why aren't more in-office procedures performed in some Latin American countries? Discussion: Despite being performed more frequently, there is still controversy whether in-office procedures should be performed as often due to the risk of complications. Furthermore, procedures that are done in the office setting are more popular in some countries than in others, even though their benefit has been well demonstrated. This article describes various in-office procedures, including biopsy, vocal fold injections, and laser surgery. We also discuss what factors might contribute to having office-procedures being performed more frequently in some countries than others. Conclusion: Awake interventions offer numerous benefits, including shorter procedure time, reduced costs, and lower patient morbidity. These advantages have significantly transformed the treatment of laryngeal diseases in modern laryngology practice in a global manner.


Introducción: El propósito de este artículo es discutir los procedimientos laríngeos en el consultorio como una alternativa a la intervención quirúrgica bajo anestesia general. Los procedimientos en consultorio se han vuelto más comunes debido a los avances tecnológicos. Como resultado, estos enfoques son menos invasivos y más amigables para el paciente, con mayor tolerancia al dolor y reducción del tiempo y costo del procedimiento. Métodos: Realizamos un análisis temático de los informes publicados sobre las intervenciones laríngeas más conocidas y realizadas. Tres preguntas guiaron nuestro análisis: ¿Qué procedimientos laringológicos se pueden realizar en el consultorio y cuales sin los más frecuentes?, ¿cuáles son las ventajas de los procedimientos laringológicos fuera del quirófano frente a los que se realizan bajo anestesia general?, ¿por qué no se realizan más procedimientos laringológicos en el consultorio en la mayoría de los países en Latinoamérica? Discusión: A pesar de que se realizan con mayor frecuencia, aún existe controversia sobre si los procedimientos en consultorio deben realizarse con tanta frecuencia debido al riesgo de complicaciones. Además, los procedimientos que se realizan en el consultorio son más populares en algunos países que en otros, aunque sus beneficios han sido bien demostrados. Este artículo describe varios procedimientos en el consultorio, incluida la biopsia, las inyecciones de cuerdas vocales y la cirugía con láser. También se discutieron los factores que podrían contribuir a que los procedimientos en el consultorio se realicen con más frecuencia en algunos países que en otros. Conclusión: Las intervenciones con pacientes despiertos ofrecen numerosos beneficios, incluido un tiempo de procedimiento más corto, costos reducidos y una menor morbilidad para el paciente. Estas ventajas han transformado significativamente el tratamiento de las enfermedades laríngeas en la práctica de la laringología moderna a nivel mundial.

2.
BMC Chem ; 18(1): 69, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600590

RESUMO

Cancer is a deadly illness with a convoluted pathogenesis. The most prevalent restrictions that frequently result in treatment failure for cancer chemotherapy include lack of selectivity, cytotoxicity, and multidrug resistance. Thus, considerable efforts have been focused in recent years on the establishment of a modernistic sector termed nano-oncology, which offers the option of employing nanoparticles (NPs) with the objective of detecting, targeting, and treating malignant disorders. NPs offer a focused approach compared to conventional anticancer methods, preventing negative side effects. In the present work, a successful synthetic process was used to create magnetic cobalt cores with an AgNPs shell to form bimetallic nanocomposites CoAg, then functionalized with Cis forming novel CoAg@Cis nanohybrid. The morphology and optical properties were determined by TEM, DLS, FTIRs and UV-vis spectroscopy, furthermore, anticancer effect of CoAg and CoAg@Cis nanohybrids were estimated using MTT assay on MCF7 and HCT cell lines. Our results showed that Co@Ag core shell is about 15 nm were formed with dark CoNPs core and AgNPs shell with less darkness than the core, moreover, CoAg@Cis has diameter about 25 nm which are bigger in size than Co@Ag core shell demonstrating the loading of Cis. It was observed that Cis, CoAg and CoAg@Cis induced a decline in cell survival and peaked at around 65%, 73%and 66% on MCF7 and 80%, 76%and 78% on HCT at 100 µg/ml respectively. Compared to Cis alone, CoAg and CoAg@Cis caused a significant decrease in cell viability. These findings suggest that the synthesized CoAg can be used as a powerful anticancer drug carrier.

3.
Lasers Med Sci ; 39(1): 113, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656631

RESUMO

PURPOSE: Melasma remains a refractory skin condition that needs to be actively explored. Azelaic acid has been used for decades as a topical agent to improve melasma through multiple mechanisms, however, there is a lack of research on its combination with laser therapy. This study evaluated the effectiveness of isolated treatment with topical 20% azelaic acid and its combination with 755-nm picosecond laser in facial melasma patients. METHODS: A randomized, evaluator-blinded, controlled study was conducted on 30 subjects with facial melasma in a single center from October 2021 to April 2022. All subjects received topical 20% azelaic acid cream (AA) for 24 weeks, and after 4 weeks, a hemiface was randomly assigned to receive 755-nm picosecond (PS) laser therapy once every 4 weeks for 3 treatments. Treatment efficacy was determined by mMASI score evaluations, dermoscopic assessment, reflectance confocal microscopy (RCM) assessments and patient's satisfaction assessments (PSA). RESULTS: Treatment with 20% azelaic acid, with or without picosecond laser therapy, significantly reduced the hemi-mMASI score (P < 0.0001) and resulted in higher patient satisfaction. Improvements in dermoscopic and RCM assessments were observed in both sides of the face over time, with no difference between the two sides. RCM exhibited better dentritic cell improvement in the combined treatment side. No patients had serious adverse effects at the end of treatment or during the follow-up period. CONCLUSION: The additional use of picosecond laser therapy showed no clinical difference except for subtle differences detected by RCM assessments.The study was registered in the Chinese Clinical Trial Registry (ChiCTR2100051294; 18 September 2021).


Assuntos
Ácidos Dicarboxílicos , Lasers de Estado Sólido , Melanose , Humanos , Melanose/terapia , Melanose/radioterapia , Feminino , Ácidos Dicarboxílicos/uso terapêutico , Ácidos Dicarboxílicos/administração & dosagem , Adulto , Pessoa de Meia-Idade , Lasers de Estado Sólido/uso terapêutico , Masculino , Resultado do Tratamento , Terapia com Luz de Baixa Intensidade/métodos , Fármacos Dermatológicos/uso terapêutico , Fármacos Dermatológicos/administração & dosagem , Terapia Combinada , Satisfação do Paciente , Administração Tópica , Método Simples-Cego
4.
Lasers Med Sci ; 39(1): 112, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656634

RESUMO

PURPOSE: To measure the dynamic characteristics of the flow field in a complex root canal model activated by two laser-activated irrigation (LAI) modalities at different activation energy outputs: photon-induced photoacoustic streaming (PIPS) and microshort pulse (MSP). METHODS: A phase-locked micro-scale Particle Image Velocimetry (µPIV) system was employed to characterise the temporal variations of LAI-induced velocity fields in the root canal following a single laser pulse. The wall shear stress (WSS) in the lateral root canal was subsequently estimated from the phase-averaged velocity fields. RESULTS: Both PIPS and MSP were able to generate the 'breath mode' of the irrigant current under all tested conditions. The transient irrigation flush in the root canal peaked at speeds close to 6 m/s. However, this intense flushing effect persisted for only about 2000 µs (or 3% of a single laser-pulse activation cycle). For MSP, the maximum WSS magnitude was approximately 3.08 Pa at an activation energy of E = 20 mJ/pulse, rising to 9.01 Pa at E = 50 mJ/pulse. In comparison, PIPS elevated the WSS to 10.63 Pa at E = 20 mJ/pulse. CONCLUSION: Elevating the activation energy can boost the peak flushing velocity and the maximum WSS, thereby enhancing irrigation efficiency. Given the same activation energy, PIPS outperforms MSP. Additionally, increasing the activation frequency may be an effective strategy to improve irrigation performance further.


Assuntos
Reologia , Humanos , Cavidade Pulpar/efeitos da radiação , Irrigação Terapêutica/métodos , Irrigação Terapêutica/instrumentação , Lasers , Irrigantes do Canal Radicular , Técnicas Fotoacústicas/métodos , Preparo de Canal Radicular/métodos , Preparo de Canal Radicular/instrumentação
5.
Angew Chem Int Ed Engl ; : e202405048, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656647

RESUMO

A major bottleneck limiting the commercialization of aqueous zinc ion batteries (AZIBs) is dendrite formation on the zinc anode during the plating/stripping process, which leads to rapid performance and device failure. In this regard, researchers are trying to design more stable anodes toward suppressing dendrite formation. One possible solution to tackle this problem and to extend the cycling life of AZIBs is to modify the zinc anode surface by coating carbonaceous materials, enabling controlled charge flux and uniform ion distribution. This work reports a sustainable and bio-derived polylactic acid (PLA) as a coating layer on the zinc anode. Carbonizing this polymer under ambient conditions using a high-power nanosecond laser forms a carbon-coated zinc foil, which was directly utilized as the anode in aqueous zinc ion batteries. The fabricated laser-processed PLA-derived carbon-coated zinc anode demonstrated an extended cycling life of almost 1600 hours, significantly outperforming the bare zinc anode. A full aqueous zinc ion battery assembled from as-modified anode and as-prepared V2O5 nanofibers as cathode was able to deliver a specific capacity of 238 mAh g-1 at 1.0 A g-1 with a capacity retention of 70 % after 1000 cycles.

6.
J Fluoresc ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656645

RESUMO

Whispering gallery mode (WGM) resonance was created in a spherical micro drop. A gradual shift in the resonance were observed. For a 600 nm droplet radius, the blue shift were 1.5, 0.7, 3.7 nm. It was estimated that such a shift corresponds to a reduction in optical radius of the droplet by 1.3, 0.6, 3.3 nm respectively. The droplet was created from a solution of glycerol, methanol and rhodamine 6G dye, and was trapped and levitated in a modified Paul trap. The WGMs were created by optically exciting the dye material from an external 532 nm cw laser beam. A shift in the WGM was observed during a gradual increase in power of the excitation laser, and a reason for such a shift was thought to be thermal evaporation of the liquid. For a larger droplet an initial 0.1 nm thermal expansion was also estimated, preceding the volume contraction. Such an expansion was negligible for a smaller droplet. The rate of change of the blue shift depends upon initial radius of the droplet. For the smaller droplet the estimated rate of change of WGM with a change in optical radius, was 0.771. For larger droplet, this rate is lower.

7.
Adv Ther ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656739

RESUMO

INTRODUCTION: Laser and radiofrequency ablation are two thermal ablation methods currently widely used to treat lower limb venous insufficiency. However, very few studies have been conducted on the use of microwaves, a form of thermal ablation, for the treatment of small saphenous vein (SSV) insufficiency. This study aimed to examine the efficacy and safety of endovenous microwave ablation (EMA) for the treatment of SSV insufficiency. METHODS: The clinical data of 126 patients (126 lower limbs) with SSV insufficiency (SSV trunk reflux time ≥ 500 ms on lower limb color Doppler ultrasound) treated at the Surgery Department of The Sixth People's Hospital of Zhuji from January 2020 to June 2022 were analyzed retrospectively; 64 patients underwent EMA and 62 underwent endovenous laser ablation (EVLA). The perioperative marker data [duration of surgery, duration of hospitalization, length of thermal ablation, duration of thermal ablation, number of incisions, and numerical pain rating scale (NPRS)], complication data [skin ecchymosis, skin burns, surgical site infection, paresthesia, deep vein thrombosis (DVT), and heat-induced thrombosis (EHIT)], venous clinical severity score (VCSS), chronic venous disease quality of life questionnaire (CIVIQ-20) before and 1, 3, 12 months after surgery, and SSV trunk occlusion rate at 12 months after surgery were compared between the two groups. RESULTS: No significant differences in the surgery or hospitalization durations were observed between the two groups. There were no significant differences in the length of the SSV that required thermal ablation between the two groups; however, the thermal ablation time was shorter in the EMA group than that in the EVLA group (6.14 ± 1.47 min vs 7.05 ± 1.16 min, P < 0.001). There were no statistical differences in the number of incisions, volume of tumescent solution used, or quantity of sclerosing foam used. The NPRS scores of the EMA group at 24 h and 72 h after surgery were significantly greater than those of the EVLA group (4.03 ± 0.98 vs 3.52 ± 1.28, P = 0.013; 3.78 ± 1.06 vs 3.15 ± 1.03, P = 0.001). Moreover, the two groups showed no significant difference in the NPRS score at 1 month (1.14 ± 0.84 vs 1.07 ± 0.75, P = 0.623). The EMA and EVLA group patients experienced similar postoperative complications. The VCSS and CIVIQ-20 score significantly improved at 1, 3, and 12 months after surgery. The VCSS and CIVIQ-20 scores were compared between the two groups at 12 months after surgery, and there were no significant differences (1.44 ± 0.63 vs 1.56 ± 0.56, P = 0.261; 24.24 ± 4.96 vs 25.19 ± 5.36, P = 0.304). There was no significant difference in the incidence of SSV trunk occlusion at 12 months after surgery between the two groups (95.31% vs 96.77%, OR 1.475; 95% CI 0.238-9.146, P = 1.000). CONCLUSION: EMA and EVLA are equally effective treatment methods for SSV insufficiency. EMA is associated with higher NPRS scores in the early postoperative period.

8.
Food Chem ; 448: 139210, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38569408

RESUMO

The detection of heavy metals in tea infusions is important because of the potential health risks associated with their consumption. Existing highly sensitive detection methods pose challenges because they are complicated and time-consuming. In this study, we developed an innovative and simple method using Ag nanoparticles-modified resin (AgNPs-MR) for pre-enrichment prior to laser-induced breakdown spectroscopy for the simultaneous analysis of Cr (III), Cu (II), and Pb (II) in tea infusions. Signal enhancement using AgNPs-MR resulted in amplification with limits of detection of 0.22 µg L-1 for Cr (III), 0.33 µg L-1 for Cu (II), and 1.25 µg L-1 for Pb (II). Quantitative analyses of these ions in infusions of black tea from various brands yielded recoveries ranging from 83.3% to 114.5%. This method is effective as a direct and highly sensitive technique for precisely quantifying trace concentrations of heavy metals in tea infusions.


Assuntos
Cromo , Cobre , Contaminação de Alimentos , Chumbo , Nanopartículas Metálicas , Prata , Chá , Chá/química , Cromo/análise , Chumbo/análise , Prata/química , Nanopartículas Metálicas/química , Cobre/análise , Contaminação de Alimentos/análise , Análise Espectral/métodos , Lasers , Camellia sinensis/química , Metais Pesados/análise , Limite de Detecção
9.
Artigo em Inglês | MEDLINE | ID: mdl-38662963

RESUMO

The stripping reaction of lithium (Li) will greatly impact the cyclability and safety of Li-metal batteries. However, Li pits' nucleation and growth, the origin of uneven stripping, are still poorly understood. In this study, we analyze the nucleation mechanism of Li pits and their morphology evolution with a large population and electrode area (>0.45 cm2). We elucidate the dependence of the pit size and density on the current density and overpotential, which are aligned with classical nucleation theory. With a confocal laser scanning microscope, we reveal the preferential stripping on certain crystal grains and a new stripping mode between pure pitting and stripping without pitting. Descriptors like circularity and the aspect ratio (R) of the pit radius to depth are used to quantify the evolution of Li pits in three dimensions. As the pits grow, growth predominates along the through-planedirection, surpassing the expanding rate in the in-plane direction. After analyzing more than 1000 pits at each condition, we validate that the overpotential is inversely related to the pit radius and exponentially related to the rate of nucleation. With this established nucleation-overpotential relationship, we can better understand and predict the evolution of the surface area and roughness of Li electrodes under different stripping conditions. The knowledge and methodology developed in this work will significantly benefit Li-metal batteries' charging/discharging profile design and the assessment of large-scale Li-metal foils.

10.
Epilepsy Behav ; 155: 109669, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38663142

RESUMO

The purpose of this study was to systematically examine three different surgical approaches in treating left medial temporal lobe epilepsy (mTLE) (viz., subtemporal selective amygdalohippocampectomy [subSAH], stereotactic laser amygdalohippocampotomy [SLAH], and anterior temporal lobectomy [ATL]), to determine which procedures are most favorable in terms of visual confrontation naming and seizure relief outcome. This was a retrospective study of 33 adults with intractable mTLE who underwent left temporal lobe surgery at three different epilepsy surgery centers who also underwent pre-, and at least 6-month post-surgical neuropsychological testing. Measures included the Boston Naming Test (BNT) and the Engel Epilepsy Surgery Outcome Scale. Fisher's exact tests revealed a statistically significant decline in naming in ATLs compared to SLAHs, but no other significant group differences. 82% of ATL and 36% of subSAH patients showed a significant naming decline whereas no SLAH patient (0%) had a significant naming decline. Significant postoperative naming improvement was seen in 36% of SLAH patients in contrast to 9% improvement in subSAH patients and 0% improvement in ATLs. Finally, there were no statistically significant differences between surgical approaches with regard to seizure freedom outcome, although there was a trend towards better seizure relief outcome among the ATL patients. Results support a possible benefit of SLAH in preserving visual confrontation naming after left TLE surgery. While result interpretation is limited by the small sample size, findings suggest outcome is likely to differ by surgical approach, and that further research on cognitive and seizure freedom outcomes is needed to inform patients and providers of potential risks and benefits with each.

11.
Appl Radiat Isot ; 209: 111328, 2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38663230

RESUMO

The possibility of laser isotope separation of 175Yb from irradiated natural Yb has been investigated. The optimum process parameters such as powers and bandwidths of the lasers, Doppler broadening and the number density of the atoms have been derived through density matrix calculations. It has been shown that it is possible to produce 175Yb (>42% enriched) at a production rate of 62 µg/hour (or 1.5 mg/day). This corresponds to the production rate of 1350 patient doses (of 7.4 GBq each) per day. The radionuclidic purity of the isotopic mixture is expected to be 99.9999%. The method is highly suitable for the countries having only low-flux nuclear reactors.

12.
Ultrasonics ; 141: 107321, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38663309

RESUMO

Far-field laser technology has greatly promoted the progress of nondestructive ultrasonic imaging of bulk structures. However, under thermoelastic excitation, the body waves exhibit a relatively low signal-to-noise ratio, resulting in images with low resolution and contrast. Based on the motivation, this paper developed a frequency-domain phase weighted imaging method to improve the quality of laser ultrasonic defect imaging. Firstly, laser ultrasonic scanning was performed on the sample with artificial transverse hole defects. The cylindrical lens focused line source was used to improve the intensity of the body wave signals, and ensure that there was no damage on the material surface under high laser energies. Then, the frequency-domain phase shift migration (PSM) algorithm was used to perform multimode imaging of defects, achieving frequency-domain synthetic aperture focusing technique (F-SAFT) and total focused method (F-TFM) imaging based on full matrix capture. Furthermore, the phase circular statistical vector (PCSV) was proposed for weighted optimization, which improved the image quality, suppressed the background noise and multimode artifacts. Finally, the imaging quality of several algorithms were discussed. The results indicate that frequency-domain images were superior to time-domain results. After phase weighting, the imaging quality can be further improved, and the detection blind zone was significantly reduced. This work will contribute to the rapid and high-quality defect imaging of laser ultrasonic.

13.
Mar Pollut Bull ; 202: 116387, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38663346

RESUMO

The concentrations of 11 heavy metals in sediments from Lake Edku, Egypt were determined using LA-ICP-MS. The average concentrations of elements occurred in the order of Fe > V > Cr > Zn > Ni > Cu > Co > Pb > As > Sn > Mo with respective values of 4.67 %, 104.8, 77.9, 76.6, 59.2, 52, 27.8, 19.8, 4.14, 2.24, and 1.45 µg/g. Several pollution indices were used to evaluate individual and cumulative contamination levels. All HMs were found to be in the deficiency to minimal enrichment range based on the enrichment factor. The contamination factor indicated low contamination levels of Cr and As, low to moderate contamination levels of Fe, Ni, Zn, Mo, Sn, and Pb, and moderate contamination levels of Co and Cu. The pollution load index and contamination degree indicated the sediments to be polluted and moderately polluted, respectively.

14.
Int Arch Allergy Immunol ; : 1-13, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38663361

RESUMO

INTRODUCTION: Allergic rhinitis (AR) is a common allergic disorder that impairs social and physical functioning as well as quality of life. It is characterized by sneezing, rhinorrhea, congestion, and itching which respond suboptimally to drug therapy. Low-level laser therapy (LLLT) has anti-inflammatory and immunosuppressive properties that have shown promise in some studies. We aimed to systematically review LLLT's effectiveness in treating AR and meta-analyze our findings. METHODS: A systematic search of PubMed, Scopus, and Web of Science was conducted on November 24, 2023. All studies investigating LLLT on AR were included, and a pre-post meta-analysis of nasal symptoms (rhinorrhea, nasal congestion, nasal itching, and sneezing) in the LLLT-treated arm was conducted. Rhinoconjunctivitis quality of life questionnaire (RQLQ) scores before and after LLLT were also meta-analyzed alongside a pairwise meta-analysis of LLLT with placebo, acupuncture, steroids/antihistamines, and ultraviolet lasers. A random-effects model was used with a conservative pre-post correlation of 0.4 and standardized mean difference (SMD) as the effect size. RESULTS: Sixteen studies were included in this review, and we found that nasal symptoms are alleviated post-LLLT in people with AR (SMD: -1.4, 95 CI: [-2.07 to -1.13], p value <0.001). RQLQ scores were also reduced after LLLT (SMD = -0.72, 95 CI: [-0.94 to -0.50], p value <0.001), and very few adverse events were reported. This meta-analysis, however, had significant publication bias and heterogeneity. When compared to a placebo, LLLT did not significantly improve nasal symptoms (SMD: -0.69, p value = 0.167), which might mean the post-LLLT nasal symptom alleviation is due to a placebo effect. Comparisons to other treatment modalities were too few to deduce anything meaningful, although it does appear that LLLT is less effective than UV lasers. CONCLUSION: LLLT is most likely effective at alleviating nasal symptomology and has a low likelihood of adverse event incidence, yet more high-quality studies with larger sample sizes are needed to compare LLLT to a placebo to ensure its superiority to the placebo effect, as well as non-inferiority clinical trials to compare it to standard treatments.

15.
Int Ophthalmol ; 44(1): 201, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38664258

RESUMO

AIM: To retrospectively evaluate the effectiveness and reliability of selective laser trabeculoplasty (SLT) treatment in juvenile open angle glaucoma (JOAG) cases. MATERIAL AND METHOD: The 46 eyes of 28 cases that had undergone SLT for JOAG and had a follow-up of at least one month were included in the study. The pre-SLT, month 1, month 6, year 1, year 2, and final follow-up intraocular pressure (IOP); the number of drugs before and after the SLT procedure; and the complications caused by the SLT were recorded. An IOP below 21 mmHg without any additional medication or glaucoma surgery and an IOP decrease of 20% or more compared to the baseline were considered successful. RESULTS: There were 18 females and 10 males with a mean age of 17.52 ± 2.7 (13-22) years. The cases were followed-up for a mean duration of 39 (5-59) months. The mean IOP was 23.93 ± 0.52 mmHg before SLT and decreased to 17.15 ± 0.57 mmHg at month 1 after the procedure, 17.17 ± 0.52 mmHg at month 6, 18.02 ± 0.77 mmHg at year 1, 18.12 ± 0.48 mmHg at year 2, and 20.93 ± 0.69 mmHg at the final follow-up. The post-SLT IOP measurements at all times were found to be significantly lower than the pre-SLT values (p < 0.001). The mean number of drugs was 1.5 before the SLT and 0.59 afterwards (p < 0.001). The most common complications after SLT were anterior chamber inflammation in 29 cases (63.04%), hyperemia in 20 (43.40%) cases (4.34%), an early period IOP increase of 5 mmHg or more in 11 cases (23.91%), and mild ocular pain in 2 cases (4.34%). CONCLUSION: SLT is an effective and reliable method for JOAG treatment.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Terapia a Laser , Trabeculectomia , Humanos , Trabeculectomia/métodos , Masculino , Feminino , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Estudos Retrospectivos , Adolescente , Terapia a Laser/métodos , Seguimentos , Adulto Jovem , Resultado do Tratamento , Tonometria Ocular , Acuidade Visual , Reprodutibilidade dos Testes
16.
Cureus ; 16(3): e56935, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38665726

RESUMO

AIM: In-vitro evaluation of shear bond strength, mode of failure, and adaptation of fifth-generation (etch-and-rinse), seventh-generation,and eighth-generation self-etch dental adhesives to human dentin with or without diode-laser irradiation before photopolymerization. MATERIALS AND METHODS: Seventy-two extracted human maxillary premolar teeth were collected. The buccal and lingual surfaces of teeth were grounded until dentin was exposed. Test areas of 4 mm diameter were created on both surfaces of teeth to standardize the area of treatment. The samples were then randomly allocated into three groups (n = 24): Group 1 Adper Single Bond 2 Etch-and-Rinse; Group 2 Tetric-N-Bond Universal Self-Etch; Group 3 Prime and Bond Universal Self-Etch dental adhesives were used. Buccal surfaces (sub-groups 'a') of all specimens were irradiated with diode laser before photopolymerization of the adhesive material, and palatal surfaces (sub-groups 'b') were directly photopolymerized without prior diode laser irradiation and restored with composite resin. All specimens were thermocycled. Four specimens from each group were then subjected to scanning electron microscopy (SEM) analysis to examine the adaptation of adhesive to dentin, and the remaining 60 specimens were evaluated for shear bond strength tests, modes of failure at the adhesive-dentin interface, and values were recorded, tabulated, and used for data analysis. A one-way ANOVA test and the Student's t-test were used for statistical analysis. A P value ≤ 0.05 was considered statistically significant. RESULTS: The mean shear bond strength for the groups was: Group 1a (13.96 MPa), 1b (14.95 MPa); Group 2a (10.06 MPa), 2b (10.30 MPa); Group 3a (12.03 MPa), and 3b (10.44 MPa). No statistically significant difference was seen among sub-groups 1a and 3a, 2a and 3a, 2b and 3b as P > 0.05. A significant difference was seen among sub-groups 1b and 3b (P<0.05), 1a and 2a, and 1b and 2b (P<0.01). CONCLUSION: Adper Single Bond 2 without diode-laser irradiation before photopolymerization showed the highest shear bond strength, followed by Adper Single Bond 2 irradiated with diode laser before photopolymerization, with the maximum adaptation of dental adhesive to dentin compared to other adhesives used either with or without diode-laser irradiation.

17.
Int J Exerc Sci ; 17(4): 327-342, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38665862

RESUMO

Objective: To conduct a meta-analysis to investigate the effects of Photobiomodulation (PBM) therapy on running performance. Introduction: PBM has recently been advocated as a valuable non-pharmacological ergogenic strategy, however, the efficacy of PBM on running performance remains unproven. Methods: A computerized literature search was conducted until June 2023. The databases searched were PubMed/Medline, Embase, Scopus, SPORTDiscus, and Web of Science. Inclusion/exclusion criteria were determined through the PICO process. The running variables analyzed were time-trial or time-to-exhaustion. Results were combined with the standardized mean differences (SMD) and the 95% confidence intervals. Results: Twelve studies fulfilled the inclusion criteria. No significant effects in favor of PBM were found (SMD = 0.13; p = 0.11). There was no effect considering the presence (SMD = 0.16; p = 0.38) and absence (SMD = 0.11; p = 0.25) of training, and there was no dose-response effect (p = 0.82). Conclusion: Our findings indicate that PBM alone or combined with a training program does not improve running performance in terms of time-trial and time-to-exhaustion testing. More studies involving PBM plus training and doses higher than 1000 J are needed to determine if PBM is effective in improving running performance.

18.
Osteoarthr Cartil Open ; 6(2): 100466, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38623306

RESUMO

Objective: A prototype infrared attenuated total reflection (IR-ATR) laser spectroscopic system designed for in vivo classification of human cartilage tissue according to its histological health status during arthroscopic surgery is presented. Prior to real-world in vivo applications, this so-called osteoarthritis (OA) scanner has been tested at in vitro conditions revealing the challenges associated with complex sample matrices and the accordingly obtained sparse spectral datasets. Methods: In vitro studies on human knee cartilage samples at different contact pressures (i.e., 0.2-0.5 â€‹MPa) allowed recording cartilage degeneration characteristic IR signatures comparable to in vivo conditions with high temporal resolution. Afterwards, the cartilage samples were assessed based on the clinically acknowledged osteoarthritis cartilage histopathology assessment (OARSI) system and correlated with the obtained sparse IR data. Results: Amide and carbohydrate signal behavior was observed to be almost identical between the obtained sparse IR data and previously measured FTIR data used for sparse partial least squares discriminant analysis (SPLSDA) to identify the spectral regions relevant to cartilage condition. Contact pressures between 0.3 and 0.4 â€‹MPa seem to provide the best sparse IR spectra for cylindrical (d â€‹= â€‹3 â€‹mm) probe tips. Conclusion: Laser-irradiating IR-ATR spectroscopy is a promising analytical technique for future arthroscopic applications to differentiate healthy and osteoarthritic cartilage tissue. However, this study also revealed that the flexible connection between the laser-based analyzer and the arthroscopic ATR-probe via IR-transparent fiberoptic cables may affect the robustness of the obtained IR data and requires further improvements.

19.
Cureus ; 16(3): e56385, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38633928

RESUMO

INTRODUCTION: The increased use of soft drinks leads to a high prevalence of dental erosion (DE), and the use of polymers can decrease tooth demineralization by a carbonated drink. Assessment of the effect of food-approved polymers such as highly esterified pectin (HP), propylene glycol alginate (PGA), and gum arabic (GA) on their efficiency to reduce enamel demineralization on addition with a commercially available carbonated drink was the main objective of this study. MATERIALS AND METHODS: For this study, 300 premolar teeth were studied for enamel erosion and were divided into five groups consisting of 60 samples in each group. The teeth treated with distilled water had negative control, a commercially available carbonated drink with pH 2.7 had positive control, and food polymers were added individually to the carbonated drink in a specified quantity with minimal pH change and were taken as groups A, B, and C, respectively. The enamel erosion that occurred in study groups was measured using a laser fluorescence spectroscopic system with laser excitation at 404 nm at different treatment times (30, 60, and 120 seconds).  Results: Demineralization was less in samples treated with polymer added to carbonated drink solutions compared to samples exposed to plain carbonated drink. As the time of exposure increased up to 120 seconds, a significant decrease in demineralization occurred in polymer-treated groups of samples as against plain carbonated drink with HP showing more decreased demineralization with extended exposure periods compared to other polymers. The surface morphology of tooth samples exhibited the anti-erosive effect of polymers, and the scanning electron microscopic pictures revealed a smoother surface for the polymer-added group. CONCLUSION: This study shows the efficacy of HP, PGA, and GA on reducing the effect of carbonated drink-induced enamel demineralization, and these polymers' addition to drinks can be an innovative way to reduce the demineralization potential of carbonated acidic drinks.

20.
Skin Res Technol ; 30(4): e13697, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38634118

RESUMO

BACKGROUND: One of the common esthetic complaints of patients is horizontal neck wrinkles that have limited treatment modality. AIM: In the present study, we evaluated the efficacy of the Endolift laser on the horizontal neck wrinkles. METHODS: Totally, 10 healthy female and male patients suffering horizontal neck wrinkles were joined in this study. All patients are treated with Endolift laser. The effect of the Endolift methods on the horizontal neck wrinkles was evaluated by biometric parameter changed results with Cutometer, Visioface, and the Skin Ultrasound Imaging system. Also, three blinded dermatologists and patients' satisfaction were evaluated. RESULTS: The Visoface results showed that the Endolift laser treatment significantly decline the depth and area of horizontal neck wrinkle. The skin ultrasonography results reported the epidermis and dermis density and thickness were significantly increased. Also, the cutometer outcomes displayed that the Endolift laser treatment can increase skin elasticity. Also, significantly a greater number of patients were well satisfied with the technique. CONCLUSION: In conclusion, Endolift laser is a safe and effective method for decreasing the horizontal neck wrinkles and improving the appearance of the neck. This procedure does not require general anesthesia and recovery time.


Assuntos
Envelhecimento da Pele , Humanos , Masculino , Feminino , Resultado do Tratamento , Satisfação do Paciente , Lasers , Biometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...